Water intelligence for Rwanda — research prototype
Designing sensor-driven monitoring and analytics for distributed water systems. This site presents a premium, responsive prototype and simulated dashboards. All datasets and experiments shown are synthetic and for illustration only.
Technical solution (system design)
Overview from the perspective of a water engineer and data scientist. This is a conceptual design for a monitoring stack tailored to Rwanda's small-town and rural water networks.
- Sensors (edge): pressure transducers, ultrasonic flow meters, turbidity probes, water level sensors, and battery-powered temperature nodes.
- Edge compute: low-power gateways that perform local aggregation, heartbeat and basic anomaly detection using rule-based thresholds and light ML models (quantile/median filters).
- Connectivity: LoRaWAN or NB-IoT gateways for low-bandwidth telemetry; intermittent synchronization to central servers.
- Cloud analytics: time-series database, ingestion pipelines, hydraulic model coupling, automated leakage/anomaly scoring, and dashboards for operators.
- Security & privacy: device authentication, TLS for uplink, role-based access for data viewers. (Prototype design only.)
Note: This is a research prototype description. No production claims are made.
Illustrative Monitoring Dashboard — SIMULATED DATA
All numbers below are simulated for design evaluation and user-interface testing.
Dashboard widgets use CSS and SVG for visualisation. All values are synthetic and intended to demonstrate UI and analytics concepts.
Simulated experiment — interpretation (research prototype)
This section outlines a controlled synthetic experiment used to validate anomaly detection logic in the prototype. No field trials are represented.
Experiment design (synthetic)
- Generate realistic time-series for pressure, flow and turbidity across 30 virtual nodes over 30 days.
- Inject simulated events: pump start/stop, gradual leakage (small sustained pressure drop), and turbidity spikes (brief peaks).
- Run rule-based detectors and a simple supervised classifier trained on labeled synthetic events to score anomalies.
Interpretation of simulated outcomes
The synthetic dataset allowed evaluation of detection sensitivity and false-positive behavior in a controlled setting. Example interpretations (SIMULATED):
- Leakage patterns produce sustained pressure drops with correlated increases in flow variance; the prototype detector flags >0.2 sustained score as medium risk.
- Short turbidity spikes are identifiable but require temporal smoothing to reduce false alarms from sensor noise.
- Network uptime simulation highlights the need for graceful degradation in dashboards when telemetry is intermittent.
These findings are illustrative and derived from synthetic data. Further field validation is required before operational use.